From 6b43e2b8599a5be8904948591d8bca6e676f5eed Mon Sep 17 00:00:00 2001 From: Eduardo Valentin Date: Wed, 13 Nov 2013 14:11:09 -0400 Subject: thermal: fix cpu_cooling max_level behavior As per Documentation/thermal/sysfs-api.txt, max_level is an index, not a counter. Thus, in case a CPU has 3 valid frequencies, max_level is expected to be 2, for instance. The current code makes max_level == number of valid frequencies, which is bogus. This patch fix the cpu_cooling device by ranging max_level properly. Reported-by: Carlos Hernandez Signed-off-by: Eduardo Valentin Signed-off-by: Zhang Rui diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index d179028..d0f8f8b5 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -173,6 +173,8 @@ static int get_property(unsigned int cpu, unsigned long input, freq = table[i].frequency; max_level++; } + /* max_level is an index, not a counter */ + max_level--; /* get max level */ if (property == GET_MAXL) { @@ -181,7 +183,7 @@ static int get_property(unsigned int cpu, unsigned long input, } if (property == GET_FREQ) - level = descend ? input : (max_level - input - 1); + level = descend ? input : (max_level - input); for (i = 0, j = 0; table[i].frequency != CPUFREQ_TABLE_END; i++) { /* ignore invalid entry */ @@ -197,7 +199,7 @@ static int get_property(unsigned int cpu, unsigned long input, if (property == GET_LEVEL && (unsigned int)input == freq) { /* get level by frequency */ - *output = descend ? j : (max_level - j - 1); + *output = descend ? j : (max_level - j); return 0; } if (property == GET_FREQ && level == j) { -- cgit v0.10.2