From cbac3cba66ab51492da53e7bf4f38da872408065 Mon Sep 17 00:00:00 2001 From: Steve French Date: Wed, 25 Apr 2007 11:46:06 +0000 Subject: [CIFS] New CIFS POSIX mkdir performance improvement (part 2) Fix incorrect parsing of return data Signed-off-by: Steve French diff --git a/fs/cifs/cifssmb.c b/fs/cifs/cifssmb.c index a7d3d8e..14de58f 100644 --- a/fs/cifs/cifssmb.c +++ b/fs/cifs/cifssmb.c @@ -1008,9 +1008,12 @@ PsxCreat: if(cpu_to_le32(FILE_CREATE) == psx_rsp->CreateAction) *pOplock |= CIFS_CREATE_ACTION; /* check to make sure response data is there */ - if(psx_rsp->ReturnedLevel != SMB_QUERY_FILE_UNIX_BASIC) - pRetData->Type = -1; /* unknown */ - else { + if(psx_rsp->ReturnedLevel != SMB_QUERY_FILE_UNIX_BASIC) { + pRetData->Type = -1; /* unknown */ +#ifdef CONFIG_CIFS_DEBUG2 + cFYI(1,("unknown type")); +#endif + } else { if(pSMBr->ByteCount < sizeof(OPEN_PSX_RSP) + sizeof(FILE_UNIX_BASIC_INFO)) { cERROR(1,("Open response data too small")); @@ -1018,7 +1021,7 @@ PsxCreat: goto psx_create_err; } memcpy((char *) pRetData, - (char *)&psx_rsp + sizeof(OPEN_PSX_RSP), + (char *)psx_rsp + sizeof(OPEN_PSX_RSP), sizeof (FILE_UNIX_BASIC_INFO)); } diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c index 9b7e0db..f74f37c 100644 --- a/fs/cifs/inode.c +++ b/fs/cifs/inode.c @@ -796,6 +796,9 @@ static void posix_fill_in_inode(struct inode *tmp_inode, cFYI(1,("unknown inode type %d",type)); } +#ifdef CONFIG_CIFS_DEBUG2 + cFYI(1,("object type: %d", type)); +#endif tmp_inode->i_uid = le64_to_cpu(pData->Uid); tmp_inode->i_gid = le64_to_cpu(pData->Gid); tmp_inode->i_nlink = le64_to_cpu(pData->Nlinks); @@ -903,6 +906,7 @@ int cifs_mkdir(struct inode *inode, struct dentry *direntry, int mode) cFYI(1, ("posix mkdir returned 0x%x", rc)); d_drop(direntry); } else { + int obj_type; if (pInfo->Type == -1) /* no return info - go query */ goto mkdir_get_info; /*BB check (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SET_UID ) to see if need to set uid/gid */ @@ -911,19 +915,36 @@ int cifs_mkdir(struct inode *inode, struct dentry *direntry, int mode) direntry->d_op = &cifs_ci_dentry_ops; else direntry->d_op = &cifs_dentry_ops; + + newinode = new_inode(inode->i_sb); + if (newinode == NULL) + goto mkdir_get_info; + /* Is an i_ino of zero legal? */ + /* Are there sanity checks we can use to ensure that + the server is really filling in that field? */ + if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) { + newinode->i_ino = + (unsigned long)pInfo->UniqueId; + } /* note ino incremented to unique num in new_inode */ + if(inode->i_sb->s_flags & MS_NOATIME) + newinode->i_flags |= S_NOATIME | S_NOCMTIME; + newinode->i_nlink = 2; + + insert_inode_hash(newinode); d_instantiate(direntry, newinode); - if (direntry->d_inode) { - int obj_type; - direntry->d_inode->i_nlink = 2; - /* already checked in POSIXCreate whether - frame was long enough */ - posix_fill_in_inode(direntry->d_inode, + + /* we already checked in POSIXCreate whether + frame was long enough */ + posix_fill_in_inode(direntry->d_inode, pInfo, &obj_type, 1 /* NewInode */); - /* could double check that we actually - * created what we thought we did ie - * a directory - */ - } +#ifdef CONFIG_CIFS_DEBUG2 + cFYI(1,("instantiated dentry %p %s to inode %p", + direntry, direntry->d_name.name, newinode)); + + if(newinode->i_nlink != 2) + cFYI(1,("unexpected number of links %d", + newinode->i_nlink)); +#endif } kfree(pInfo); goto mkdir_out; -- cgit v0.10.2