diff options
author | David S. Miller <davem@davemloft.net> | 2016-08-30 04:54:02 (GMT) |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2016-08-30 04:54:02 (GMT) |
commit | 6abdd5f5935fff978f950561f3c5175eb34dad73 (patch) | |
tree | 6f3ed3a4f4af9e74436ec9355ebf8201357f1c40 /drivers/thermal/cpu_cooling.c | |
parent | 0b498a52778368ff501557d68c7b50878ab1701e (diff) | |
parent | e4e98c460ad38c78498622a164fd5ef09a2dc9cb (diff) | |
download | linux-6abdd5f5935fff978f950561f3c5175eb34dad73.tar.xz |
Merge git://git.kernel.org/pub/scm/linux/kernel/git/davem/net
All three conflicts were cases of simple overlapping
changes.
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/thermal/cpu_cooling.c')
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 21 |
1 files changed, 16 insertions, 5 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 3788ed7..a32b417 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -740,12 +740,22 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, } /* Bind cpufreq callbacks to thermal cooling device ops */ + static struct thermal_cooling_device_ops cpufreq_cooling_ops = { .get_max_state = cpufreq_get_max_state, .get_cur_state = cpufreq_get_cur_state, .set_cur_state = cpufreq_set_cur_state, }; +static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = { + .get_max_state = cpufreq_get_max_state, + .get_cur_state = cpufreq_get_cur_state, + .set_cur_state = cpufreq_set_cur_state, + .get_requested_power = cpufreq_get_requested_power, + .state2power = cpufreq_state2power, + .power2state = cpufreq_power2state, +}; + /* Notifier for cpufreq policy change */ static struct notifier_block thermal_cpufreq_notifier_block = { .notifier_call = cpufreq_thermal_notifier, @@ -795,6 +805,7 @@ __cpufreq_cooling_register(struct device_node *np, struct cpumask temp_mask; unsigned int freq, i, num_cpus; int ret; + struct thermal_cooling_device_ops *cooling_ops; cpumask_and(&temp_mask, clip_cpus, cpu_online_mask); policy = cpufreq_cpu_get(cpumask_first(&temp_mask)); @@ -850,10 +861,6 @@ __cpufreq_cooling_register(struct device_node *np, cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus); if (capacitance) { - cpufreq_cooling_ops.get_requested_power = - cpufreq_get_requested_power; - cpufreq_cooling_ops.state2power = cpufreq_state2power; - cpufreq_cooling_ops.power2state = cpufreq_power2state; cpufreq_dev->plat_get_static_power = plat_static_func; ret = build_dyn_power_table(cpufreq_dev, capacitance); @@ -861,6 +868,10 @@ __cpufreq_cooling_register(struct device_node *np, cool_dev = ERR_PTR(ret); goto free_table; } + + cooling_ops = &cpufreq_power_cooling_ops; + } else { + cooling_ops = &cpufreq_cooling_ops; } ret = get_idr(&cpufreq_idr, &cpufreq_dev->id); @@ -885,7 +896,7 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_dev->id); cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev, - &cpufreq_cooling_ops); + cooling_ops); if (IS_ERR(cool_dev)) goto remove_idr; |