Age | Commit message (Collapse) | Author |
|
Commmit af40a94aba "regulator: palmas: Use devm_regulator_register" missed
removing a regulator_unregister() call if palmas_extreg_init falis. Fix it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Sachin Kamat <sachin.kamat@linaro.org>
Signed-off-by: Mark Brown <broonie@linaro.org>
|
|
devm_* simplifies the code.
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Signed-off-by: Mark Brown <broonie@linaro.org>
|
|
|
|
SMPS10 has two outputs OUT1 and OUT2 and have one input IN1.
SMPS10-OUT2 is connected to SMPS10-IN1 and can be configured either
in BOOST mode or BYPASS mode. regulator_enable of SMPS10-OUT2 configures
it in BOOST mode. For BYPASS mode regulator_allow_bypass() API can be
used. SMPS10-OUT1 is connected to SMPS10-OUT2 and can be enabled using
regulator_enable().
[ axel.lin@ingics.com : Simplify regulator_desc setting for SMPS10_[OUT1|OUT2]
Signed-off-by: J Keerthy <j-keerthy@ti.com>
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
|
|
Use the wrapper function for retrieving the platform data instead of
accessing dev->platform_data directly.
Signed-off-by: Jingoo Han <jg1.han@samsung.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
|
|
Add TPS659038 support.
Signed-off-by: J Keerthy <j-keerthy@ti.com>
Acked-by: Mark Brown <broonie@linaro.org>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
|
|
The SMPS10 regulator is not presesnt in all the variants
of the PALMAS PMIC family. Hence adding a feature to distingush
between them.
Signed-off-by: J Keerthy <j-keerthy@ti.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
|
|
regulator_enable_regmap() uses enable_reg to enable the regulator.
But enable_reg for smps10 points to SMPS10_STATUS which is a
read-only register. Fixed the same by having enable_reg
set to SMPS10_CTRL.
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Cc: stable@vger.kernel.org
|
|
Since 'id' cannot take two values at the same time, the condition
should probably be an OR (||) instead of AND (&&).
Introduced by commit 28d1e8cd67 ("regulator: palma: add ramp delay
support through regulator constraints").
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
|
|
Datasheet says:
Time Step (TSTEP) selection, when changing the output voltage, the new value is
reached through successive voltage steps (if not bypassed). The equivalent
programmable slew rate of the output voltage is:
TSTEP[1:0]: 00 Jump (no slope control)
TSTEP[1:0]: 01 10mV/us
TSTEP[1:0]: 10 5mV/us (default)
TSTEP[1:0]: 11 2.5mV/us
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
The ctrl_addr setting for SMPS10 is missed, thus palmas_smps_init() read/write
wrong register for SMPS10 in current code. Fix it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
SMPS3 and SMPS7 do not have tstep_addr setting, so current code actually
writes 0 to smps12_ctl (offset is 0) register when set_ramp_delay callback
is called for SMPS3 and SMPS7.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
When SMPS45 is set to off and LDO8 tracking is enabled, the output voltage can
be set from 0.45 to 1.65 V. Thus set min_uV to be 450000.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
The Palma device like TPS65913 have the mode mask which is also
used for enable/disable the rails. The mode bits are defined as
00: OFF
01: AUTO
10: ECO
11: Forced PWM
and modes are set accordingly as
REGULATOR_MODE_NORMAL: AUTO
REGULATOR_MODE_IDLE: ECO
REGULATOR_MODE_FAST: PWM
Two issue observed:
1. If client calls following sequence:
regulator_enable(),
regulator_set_mode(FAST),
regulator_disable()
and again the regulator_enable() then the mode is reset
to NORMAL inplace of keeping the mode as FAST.
Fixing this by storing the current mode configured by client
and restoring modes when enable() is called after disable().
2. In following sequence, the regulator get enabled:
regulator_disable()
regulator_set_mode(FAST),
Fixing this by updating new mode in register only if it is
enabled.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Currently Palma regulator driver support the ramp delay
through rail specific platform data.
As regulator framework support the configuration of ramp
delay through regulator constraint, using the framework
method and removing the platform specific data approach.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
LDO8 of Palma device like tps65913 support the tracking mode
on which LDO8 track the SMPS45 voltage when SMPS45 is ON
and use the LDO8.VOLTAGE_SEL register when SMPS45 is OFF.
On track mode, the steps of voltage change for LDO8 is 25mV
where in non-tracking mode it is 50mV. Set the steps accordingly.
Number of voltage count is still same for both the cases.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Palmas device have control outputs like REGEN1, REGEN2, REGEN3,
SYSEN1 and SYSEN2. These control outputs can be used for controlling
external voltage switches to enabled/disable voltage outputs.
Add support of these control outputs through regulator framework.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Clear the sleep/warm reset bits when it is not selected through
regulator platform data. This will make sure that configuration
is inline with the platform data regardless of boot/POR
configuration.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Palmas regulator support the different input supply pins for each of
the rails. Fill the regulator info data with their input supply pin
names.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Signed-off-by: Ian Lartey <ian@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
When palmas regulator probe creates stack dump during initialization
due to some crash, it prints the call trace as follows:
[3.166321] [<c028fa20>] (_regmap_read+0x5c/0xa8) from [<c028fab0>] (regmap_read+0x44/0x5c)
[3.174669] [<c028fab0>] (regmap_read+0x44/0x5c) from [<c023062c>] (palmas_probe+0x240/0x7d0)
[3.183193] [<c023062c>] (palmas_probe+0x240/0x7d0) from [<c0284064>] (platform_drv_probe+0x14/0x18)
[3.192322] [<c0284064>] (platform_drv_probe+0x14/0x18) from [<c0282ee4>] (driver_probe_device+0x104/0x214)
[3.202055] [<c0282ee4>] (driver_probe_device+0x104/0x214) from [<c028167c>] (bus_for_each_drv+0x5c/0x88)
The palmas_probe is current name but it helps on debugging if the
function name is more appropriate to the sub-module name.
Renaming the palmas_probe() to palmas_regulator_probe() and
palmas_remove() to palams_regulator_remove().
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
It does not make sense to assign return value of of_property_read_u32() to
pdata->reg_init[idx]->warm_reset. Use of_property_read_bool() to read
"ti,warm-reset" DT property instead which will return correct setting
for pdata->reg_init[idx]->warm_reset.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Fix the DT parsing to agree with the bindings document. Some small changes
to the value names and also fix the handling of boolean values. They were
previously using prop = 1/0, now just use of_property_read_bool calls.
Signed-off-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
DT node properties should not have "_". Replacing them by "-".
Signed-off-by: J Keerthy <j-keerthy@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Number of voltages for SMPS regulators was off by one.
Signed-off-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Ian Lartey <ian@slimlogic.co.uk>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
|
|
Current code read "ti,warm_reset" of property twice, and set
pdata->reg_init[idx]->warm_reset twice. Read and set it once is enough.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
of_find_node_by_name() returns a node pointer with refcount incremented, use
of_node_put() on it when done.
of_find_node_by_name() will call of_node_put() against from parameter,
thus we also need to call of_node_get(from) before calling
of_find_node_by_name().
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
CONFIG_HOTPLUG is going away as an option. As a result, the __dev*
markings need to be removed.
This change removes the use of __devinit, __devexit_p, __devinitdata,
__devinitconst, and __devexit from these drivers.
Based on patches originally written by Bill Pemberton, but redone by me
in order to handle some of the coding style issues better, by hand.
Cc: Bill Pemberton <wfp5p@virginia.edu>
Cc: Liam Girdwood <lrg@ti.com>
Cc: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
|
|
|
|
|
|
regulator_[get|set]_voltage_sel_regmap
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
[get|set]_voltage_sel
Don't adjust the selector in [get|set]_voltage_sel, fix it in list_voltage() instead.
For smps*(except smps10), the vsel reg-value and voltage mapping as below:
reg-value volt (uV) ( Assume RANGE is x1 )
0 0
1 500000
2 500000
3 500000
4 500000
5 500000
6 500000 (0.49V + 1 * 0.01V) * RANGE
7 510000 (0.49V + 2 * 0.01V) * RANGE
8 520000 (0.49V + 3 * 0.01V) * RANGE
9 530000 (0.49V + 4 * 0.01V) * RANGE
....
The linear mapping is start from selector 6.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
CONFIG_HOTPLUG is going away as an option so __devexit is no
longer needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
CONFIG_HOTPLUG is going away as an option so __devinit is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
CONFIG_HOTPLUG is going away as an option so __devexit_p is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
git://git.kernel.org/pub/scm/linux/kernel/git/sameo/mfd-2.6
Pull MFD changes from Samuel Ortiz:
"MFD bits for the 3.7 merge window.
As usual we have a few new drivers:
- TI LP8788
- TI OMAP USB TLL
- Maxim MAX8907
- SMSC ECE1099
- Dialog Semiconductor DA9055
- A simpler syscon driver that allow us to get rid of the anatop one.
Drivers are also gradually getting Device Tree and IRQ domain support.
The following drivers got DT support:
- palmas, 88pm860x, tc3589x and twl4030-audio
And those ones now use the IRQ domain APIs:
- 88pm860x, tc3589x, db8500_prcmu
Also some other interesting changes:
- Intel's ICH LPC now supports Lynx Point
- TI's twl4030-audio added a GPO child
- tps6527 enabled its backlight subdevice
- The twl6030 pwm driver moved to the new PWM subsystem
And finally a bunch of cleanup and casual fixes for mc13xxx, 88pm860x,
palmas, ab8500, wm8994, wm5110, max8907 and the tps65xxx family."
Fix up various annoying conflicts: the DT and IRQ domain support came in
twice and was already in 3.6. And then it was apparently rebased.
Guys, DON'T REBASE!
* tag 'mfd-3.7-1' of git://git.kernel.org/pub/scm/linux/kernel/git/sameo/mfd-2.6: (89 commits)
ARM: dts: Enable 88pm860x pmic
mfd: 88pm860x: Move gpadc init into touch
mfd: 88pm860x: Device tree support
mfd: 88pm860x: Use irqdomain
mfd: smsc: Add support for smsc gpio io/keypad driver
backlight: tps65217_bl: Add missing platform_set_drvdata in tps65217_bl_probe
mfd: DA9055 core driver
mfd: tps65910: Add alarm interrupt of TPS65910 RTC to mfd device list
mfd: wm5110: Add register patches for revision B
mfd: wm5110: Disable control interface error report for WM5110 rev B
mfd: max8907: Remove regulator-compatible from DT docs
backlight: Add TPS65217 WLED driver
mfd: Add backlight as subdevice to the tps65217
mfd: Provide the PRCMU with its own IRQ domain
mfd: Fix max8907 sparse warning
mfd: Add lp8788 mfd driver
mfd: dbx500: Provide a more accurate smp_twd clock
mfd: rc5t583: Fix warning messages
regulator: palmas: Add DT support
mfd: palmas: Change regulator defns to better suite DT
...
|
|
Add DT support to palmas regulator. This involved a little change to
the platform data structure. Regulator information can now come from
platform data or DT.
Signed-off-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
|
|
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Fix below error handling cases:
1. If reading PALMAS_SMPS_CTRL fails, simply returns ret rather than goto
err_unregister_regulator because we have not call regulator_register().
2. If palmas_ldo_init() fails, we need to call regulator_unregister() for the
regulator we just successfully registered in this for loop iteration.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Current code uses wrong calls palmas_smps_[read|write] in palmas_ldo_init(),
should be palmas_ldo_[read|write] instead.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
This patch fixes below issues when choosing selector:
1. Current code returns negative selector if min_uV < 900000 which is wrong.
For example, it is possible to satisfy the request with selector = 1 if
the requested min_uV is 850000.
2. Current code may select a voltage lower than requested min_uV.
For example, if the requested min_uV is 945000, current code chooses
selector = 1 which is lower than requested min_uV.
DIV_ROUND_UP to avoid this case.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
The logic of calculating selector in palmas_map_voltage_smps() does not match
the logic to list voltage in palmas_list_voltage_smps().
We use below equation to calculate voltage when selector > 0:
voltage = (0.49V + (selector * 0.01V)) * RANGE
RANGE is either x1 or x2
So we need to take into account with the multiplier set in VSEL register when
calculating selector in palmas_map_voltage_smps()
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
Linux 3.5-rc5 collides with further development.
Conflicts:
drivers/regulator/tps65023-regulator.c
|
|
Linux 3.5-rc4 contains patches which conflict with some of the
development work.
|
|
I forgot to apply the offsets for the regmap helper functions for
enable/disable on SMPS10 and the LDO regulators. This means regulators
will not enable/disable correctly.
Signed-off-by: Graeme Gregory <gg@slimlogic.co.uk>
Tested-by: Sebastien Guiriec <s-guiriec@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|
|
It's a little bit hard to read that the "else" case means id == PALMAS_REG_SMPS10.
if (id != PALMAS_REG_SMPS10){
do something for the cases id != PALMAS_REG_SMPS10;
} else {
do something for the case id == PALMAS_REG_SMPS10;
}
This patch changes above syntax to switch statement.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
|