summaryrefslogtreecommitdiff
path: root/arch/powerpc/cpu/mpc85xx/Kconfig
diff options
context:
space:
mode:
Diffstat (limited to 'arch/powerpc/cpu/mpc85xx/Kconfig')
-rw-r--r--arch/powerpc/cpu/mpc85xx/Kconfig25
1 files changed, 25 insertions, 0 deletions
diff --git a/arch/powerpc/cpu/mpc85xx/Kconfig b/arch/powerpc/cpu/mpc85xx/Kconfig
index 307a45d..0a4fa42 100644
--- a/arch/powerpc/cpu/mpc85xx/Kconfig
+++ b/arch/powerpc/cpu/mpc85xx/Kconfig
@@ -348,6 +348,7 @@ config ARCH_B4860
config ARCH_BSC9131
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -356,6 +357,7 @@ config ARCH_BSC9131
config ARCH_BSC9132
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -365,6 +367,7 @@ config ARCH_BSC9132
config ARCH_C29X
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -455,6 +458,7 @@ config ARCH_MPC8572
config ARCH_P1010
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -464,6 +468,7 @@ config ARCH_P1010
config ARCH_P1011
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -473,6 +478,7 @@ config ARCH_P1011
config ARCH_P1020
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -482,6 +488,7 @@ config ARCH_P1020
config ARCH_P1021
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -491,6 +498,7 @@ config ARCH_P1021
config ARCH_P1022
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -508,6 +516,7 @@ config ARCH_P1023
config ARCH_P1024
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -517,6 +526,7 @@ config ARCH_P1024
config ARCH_P1025
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -526,6 +536,8 @@ config ARCH_P1025
config ARCH_P2020
bool
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
+ select SYS_FSL_ERRATUM_ESDHC_A001
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -536,6 +548,7 @@ config ARCH_P2041
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -545,6 +558,7 @@ config ARCH_P3041
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -554,6 +568,9 @@ config ARCH_P4080
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
+ select SYS_FSL_ERRATUM_ESDHC13
+ select SYS_FSL_ERRATUM_ESDHC135
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -563,6 +580,7 @@ config ARCH_P5020
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -572,6 +590,7 @@ config ARCH_P5040
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -584,6 +603,7 @@ config ARCH_T1023
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_DDR4
select SYS_FSL_HAS_SEC
@@ -594,6 +614,7 @@ config ARCH_T1024
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_DDR4
select SYS_FSL_HAS_SEC
@@ -604,6 +625,7 @@ config ARCH_T1040
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_DDR4
select SYS_FSL_HAS_SEC
@@ -614,6 +636,7 @@ config ARCH_T1042
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_DDR4
select SYS_FSL_HAS_SEC
@@ -624,6 +647,7 @@ config ARCH_T2080
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE
@@ -633,6 +657,7 @@ config ARCH_T2081
bool
select E500MC
select FSL_LAW
+ select SYS_FSL_ERRATUM_ESDHC111
select SYS_FSL_HAS_DDR3
select SYS_FSL_HAS_SEC
select SYS_FSL_SEC_BE