Age | Commit message (Collapse) | Author |
|
Fix calculation. do_div can not handle negative values.
Use div_s64_rem to handle the calculation.
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Cc: Stefano Babic <sbabic@denx.de>
|
|
>From IC guys:
"
After a thorough accuracy study of the Temp sense circuit,
we found that with our current equation, an average part can
read 7 degrees lower than a known forced temperature.
We also found out that the standard variance was around 2C;
which is the tightest distribution that we could create.
We need to change the temp sense equation to center the average
part around the target temperature.
"
New equation:
Tmeas = (Nmeas - n1) / slope + t1 + offset
n1= fused room count
t1= 25
offset=3.580661
slope= 0.4148468 – 0.0015423*n1
According the new equation, update the thermal driver.
c1 and c2 changed to u64 type and update comments.
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Cc: Stefano Babic <sbabic@denx.de>
|
|
The thermal drivers support i.MX6 and i.MX7, add MX7 in Kconfig file.
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Cc: Stefano Babic <sbabic@denx.de>
|
|
Added kconfig for IMX_THERMAL driver.
Cc: Simon Glass <sjg@chromium.org>
Cc: Fabio Estevam <fabio.estevam@nxp.com>
Cc: Stefano Babic <sbabic@denx.de>
Cc: Peng Fan <peng.fan@nxp.com>
Cc: Matteo Lisi <matteo.lisi@engicam.com>
Cc: Michael Trimarchi <michael@amarulasolutions.com>
Signed-off-by: Jagan Teki <jagan@amarulasolutions.com>
|
|
Spelling corrections for (among other things):
* environment
* override
* variable
* ftd (should be "fdt", for flattened device tree)
* embedded
* FTDI
* emulation
* controller
|
|
To TO1.0, we can not rely on finish bit to read temperature. But to
TO1.1, the issue was fixed by IC, we can rely on finish bit for
temperature reading for TO1.1.
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Cc: Stefano Babic <sbabic@denx.de>
Cc: Tim Harvey <tharvey@gateworks.com>
Cc: Fabio Estevam <fabio.estevam@freescale.com>
Cc: Adrian Alonso <aalonso@freescale.com>
|
|
It is not very useful to have the message below on every boot
(especially when we are using early silicon):
U-Boot 2015.10-rc2-23945-g37cf215 (Sep 08 2015 - 14:12:14 -0300)
CPU: Freescale i.MX6UL rev1.0 792 MHz (running at 396 MHz)
CPU: Commercial temperature grade (0C to 95C)CPU: Thermal invalid data, fuse: 0x0
- invalid sensor device
, so turn the error message into debug level.
Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
|
|
Add imx7 SoC thermal driver support
Signed-off-by: Adrian Alonso <aalonso@freescale.com>
|
|
Rework imx_thermal driver to be used across i.MX
processor that support thermal sensor
Signed-off-by: Adrian Alonso <aalonso@freescale.com>
Signed-off-by: Peng Fan <Peng.Fan@freescale.com>
|
|
The temperature calculation must be typecasted to keep the compiler
from sign extending a negative value prior to division.
This fixes an issue where if the CPU temperature is <0C it will get stuck
in the busywait loop until the CPU heats up to 0C.
Cc: Ye Li <b37916@freescale.com>
Cc: Jason Liu <r64343@freescale.com>
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
|
|
Remove the check for temperature being within the min/max range and enter the
busywait cooling loop whenever the CPU temperature is over the critical temp.
This fixes the issue where if a board was booted at a temp greater than
the CPU temperature max, it would skip the loop and never indicate or try
to address the overtemp issue.
Cc: Ye Li <b37916@freescale.com>
Cc: Jason Liu <r64343@freescale.com>
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
|
|
The CPU temperature grade from OTP is now used to define the critical
threshold at which point we busyloop until we are below, however this
threshold is still too low.
Instead of 20C below the max CPU temperature, change it to 5C defined now
by TEMPERATURE_HOT_DETLA for clarity. Rename 'passive' to 'critical'
as that better defines our use case here. Additionally change the output
of the busyloop message to show the max CPU temperature as well as current.
Before:
CPU Temperature is 101 C, too hot to boot, waiting...
CPU Temperature is 101 C, too hot to boot, waiting...
After:
CPU Temperature (101C) too close to max (105C) waiting...
CPU Temperature (101C) too close to max (105C) waiting...
Cc: Stefan Roese <sr@denx.de>
Cc: Eric Nelson <eric.nelson@boundarydevices.com>
Cc: Heiko Schocher <hs@denx.de>
Cc: Nikita Kiryanov <nikita@compulab.co.il>
Cc: Jon Nettleton <jon.nettleton@gmail.com>
Cc: Jason Liu <r64343@freescale.com>
Cc: Ye Li <b37916@freescale.com>
Cc: Fabio Estevam <fabio.estevam@freescale.com>
Cc: Christian Gmeiner <christian.gmeiner@gmail.com>
Cc: Markus Niebel <Markus.Niebel@tq-group.com>
Cc: Peng Fan <b51431@freescale.com>
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
|
|
Replace the hard-coded values for min/max/passive with values derived from
the CPU temperature grade.
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
|
|
Expand the help messages for each driver. Add missing Kconfig for I2C,
SPI flash and thermal.
Signed-off-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Masahiro Yamada <yamada.m@jp.panasonic.com>
|
|
Printing the calibration data on every boot does not provide really useful
information:
U-Boot 2015.01-rc1-18266-ge7eb277 (Nov 24 2014 - 11:29:51)
CPU: Freescale i.MX6Q rev1.2 at 792 MHz
CPU: Thermal calibration data: 0x5d85067d
CPU: Temperature 33 C
Reset cause: POR
Board: MX6-SabreSD
Do not display the calibration data in order to have a cleaner boot log.
Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
|
|
Add a new thermal uclass for thermal sensor and implement the imx
thermal driver basing on this uclass.
Signed-off-by: Ye.Li <B37916@freescale.com>
Acked-by: Stefano Babic <sbabic@denx.de>
|