summaryrefslogtreecommitdiff
path: root/drivers/net/phy
diff options
context:
space:
mode:
authorSven Eckelmann <sven@open-mesh.com>2013-01-23 19:12:39 (GMT)
committerJohn W. Linville <linville@tuxdriver.com>2013-01-30 20:06:42 (GMT)
commit4ab0b0aa57a794ce299b0192e924379d7353beef (patch)
treed4d26f83abeed0596abdc5c1918af66c29da81a9 /drivers/net/phy
parent3a325565c7fa0ba7fd1e319c5fd07665a092fb89 (diff)
downloadlinux-fsl-qoriq-4ab0b0aa57a794ce299b0192e924379d7353beef.tar.xz
ath9k: Update spectral scan output data
The sample data received through the spectral scan can be either in big or little endian byteorder. This information isn't stored in the output file. Therefore it is not possible for the analyzer software to find the correct byte order. It is relative common to get the data from a low end AP in big endian mode and transfer it to another computer in little endian mode to analyze it. Therefore, it would be better to store it in network (big endian) byte order. The extension of the 8 bit bins for each bin to 16 bit is not necessary. This operation can be done in userspace or on a different machine. Instead the max_exp defining the amount of shifting required for each bin is exported to userspace. The change of the output format requires a change of the type in the sample tlv to allow the userspace program to correctly detect the bin format. Reported-by: Zefir Kurtisi <zefir.kurtisi@neratec.com> Signed-off-by: Sven Eckelmann <sven@open-mesh.com> [siwu@hrz.tu-chemnitz.de: squashed patches, update commit message, rebase, fix endianess bug] Signed-off-by: Simon Wunderlich <siwu@hrz.tu-chemnitz.de> Signed-off-by: Mathias Kretschmer <mathias.kretschmer@fokus.fraunhofer.de> Signed-off-by: John W. Linville <linville@tuxdriver.com>
Diffstat (limited to 'drivers/net/phy')
0 files changed, 0 insertions, 0 deletions