diff options
author | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-06-10 01:05:16 (GMT) |
---|---|---|
committer | Guenter Roeck <guenter.roeck@ericsson.com> | 2011-07-28 07:17:33 (GMT) |
commit | dabaa0d2b4085a2037d80a40b86ba215f00b601e (patch) | |
tree | 1be3184d5eff3d571a66db264ed3e68f989c85e7 /Documentation/vm | |
parent | 731b4cace10f105a81d622b70f9a35f577612d63 (diff) | |
download | linux-fsl-qoriq-dabaa0d2b4085a2037d80a40b86ba215f00b601e.tar.xz |
hwmon: (max1668) Add support for tempX_fault attributes
MAX1668 and compatibles have several external temperature sensors, but only a
single FAULT status bit. If a fault occurs, the temperature reported on the
affected sensors is 127 degrees C. Use this knowledge to report fault on
external sensors.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Diffstat (limited to 'Documentation/vm')
0 files changed, 0 insertions, 0 deletions