authorJoe Eykholt <jeykholt@cisco.com>2009-11-03 19:50:21 (GMT)
committerJames Bottomley <James.Bottomley@suse.de>2009-12-04 18:01:27 (GMT)
commitb94f8951bf256674eca3f2a490df17521442afef (patch)
treeae6b246eb65f7ef73167a2b582ce7e670158a958 /ipc
parentbe276cbe1bd680ab1f6c297017dd658e5a6b10d2 (diff)
downloadlinux-fsl-qoriq-b94f8951bf256674eca3f2a490df17521442afef.tar.xz
[SCSI] libfc fcoe: increase ELS and CT timeouts
The FC-LS spec. says ELS timeouts should be 2 x R_A_TOV. The FC-GS spec. says CT timeouts should be 3 x R_A_TOV. We've been using E_D_TOV for both of those. Change for all ELS and CT requests except FLOGI, which we leave at 2 seconds (using E_D_TOV). One could argue that R_A_TOV is locally determined until after FLOGI succeeds. This does change FLOGI for vports which becomes FDISC. This does not change the REC/SRR timeout which is 2 seconds. Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Robert Love <robert.w.love@intel.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>