diff --git a/Documentation/hwmon/w83627hf b/Documentation/hwmon/w83627hf
index bbeaba6..7922319 100644
--- a/Documentation/hwmon/w83627hf
+++ b/Documentation/hwmon/w83627hf
@@ -18,6 +18,10 @@ Supported chips:
Prefix: 'w83637hf'
Addresses scanned: ISA address retrieved from Super I/O registers
Datasheet: http://www.winbond.com/PDF/sheet/w83637hf.pdf
+ * Winbond W83687THF
+ Prefix: 'w83687thf'
+ Addresses scanned: ISA address retrieved from Super I/O registers
+ Datasheet: Provided by Winbond on request
Authors:
Frodo Looijaard <frodol@dds.nl>,
diff --git a/Documentation/hwmon/w83781d b/Documentation/hwmon/w83781d
index e545933..b1e9f80 100644
--- a/Documentation/hwmon/w83781d
+++ b/Documentation/hwmon/w83781d
@@ -36,6 +36,11 @@ Module parameters
Use 'init=0' to bypass initializing the chip.
Try this if your computer crashes when you load the module.
+* reset int
+ (default 0)
+ The driver used to reset the chip on load, but does no more. Use
+ 'reset=1' to restore the old behavior. Report if you need to do this.
+
force_subclients=bus,caddr,saddr,saddr
This is used to force the i2c addresses for subclients of
a certain chip. Typical usage is `force_subclients=0,0x2d,0x4a,0x4b'
@@ -123,6 +128,25 @@ When an alarm goes off, you can be warned by a beeping signal through
your computer speaker. It is possible to enable all beeping globally,
or only the beeping for some alarms.
+Individual alarm and beep bits:
+
+0x000001: in0
+0x000002: in1
+0x000004: in2
+0x000008: in3
+0x000010: temp1
+0x000020: temp2 (+temp3 on W83781D)
+0x000040: fan1
+0x000080: fan2
+0x000100: in4
+0x000200: in5
+0x000400: in6
+0x000800: fan3
+0x001000: chassis
+0x002000: temp3 (W83782D and W83627HF only)
+0x010000: in7 (W83782D and W83627HF only)
+0x020000: in8 (W83782D and W83627HF only)
+
If an alarm triggers, it will remain triggered until the hardware register
is read at least once. This means that the cause for the alarm may
already have disappeared! Note that in the current implementation, all