diff options
author | Mitch Williams <mitch.a.williams@intel.com> | 2015-04-27 18:57:13 (GMT) |
---|---|---|
committer | Jeff Kirsher <jeffrey.t.kirsher@intel.com> | 2015-07-15 01:26:42 (GMT) |
commit | e995163cdcf9b70c7840a8d6a7ea7c0ce81c761b (patch) | |
tree | dedf61d8af67dac9567cb37e22c343cb87976a72 | |
parent | cb2f65bc0c64015e8fa45fe1065ad241bf31a994 (diff) | |
download | linux-e995163cdcf9b70c7840a8d6a7ea7c0ce81c761b.tar.xz |
i40e: correctly program filters for VFs
MAC filters for VFs were being programmed with 0 for the VLAN value when
there was no VLAN assigned. This is incorrect and actually assigns the
VF to VLAN 0. Instead, we must use -1 to indicate that no VLAN is in
use. This change programs the filters correctly and gets rid of a bogus
error message when setting a port VLAN on an active VF.
Change-ID: Ica9a9906d768405377ff3308e27f7d0b5b2ea96e
Signed-off-by: Mitch Williams <mitch.a.williams@intel.com>
Tested-by: Jim Young <james.m.young@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
-rw-r--r-- | drivers/net/ethernet/intel/i40e/i40e_virtchnl_pf.c | 9 |
1 files changed, 6 insertions, 3 deletions
diff --git a/drivers/net/ethernet/intel/i40e/i40e_virtchnl_pf.c b/drivers/net/ethernet/intel/i40e/i40e_virtchnl_pf.c index 433e803..4070a22 100644 --- a/drivers/net/ethernet/intel/i40e/i40e_virtchnl_pf.c +++ b/drivers/net/ethernet/intel/i40e/i40e_virtchnl_pf.c @@ -542,11 +542,13 @@ static int i40e_alloc_vsi_res(struct i40e_vf *vf, enum i40e_vsi_type type) if (vf->port_vlan_id) i40e_vsi_add_pvid(vsi, vf->port_vlan_id); f = i40e_add_filter(vsi, vf->default_lan_addr.addr, - vf->port_vlan_id, true, false); + vf->port_vlan_id ? vf->port_vlan_id : -1, + true, false); if (!f) dev_info(&pf->pdev->dev, "Could not allocate VF MAC addr\n"); - f = i40e_add_filter(vsi, brdcast, vf->port_vlan_id, + f = i40e_add_filter(vsi, brdcast, + vf->port_vlan_id ? vf->port_vlan_id : -1, true, false); if (!f) dev_info(&pf->pdev->dev, @@ -2023,7 +2025,8 @@ int i40e_ndo_set_vf_mac(struct net_device *netdev, int vf_id, u8 *mac) } /* delete the temporary mac address */ - i40e_del_filter(vsi, vf->default_lan_addr.addr, vf->port_vlan_id, + i40e_del_filter(vsi, vf->default_lan_addr.addr, + vf->port_vlan_id ? vf->port_vlan_id : -1, true, false); /* Delete all the filters for this VSI - we're going to kill it |