bnx2x: Use the correct divisor value for PHC clock readings.
Time Sync (PTP) implementation uses the divisor/shift value for converting the clock ticks to nanoseconds. Driver currently defines shift value as 1, this results in the nanoseconds value to be calculated as half the actual value. Hence the user application fails to synchronize the device clock value with the PTP master device clock. Need to use the 'shift' value of 0. Signed-off-by: Sony.Chacko <Sony.Chacko@cavium.com> Signed-off-by: Sudarsana Reddy Kalluru <Sudarsana.Kalluru@cavium.com> Signed-off-by: Yuval Mintz <Yuval.Mintz@cavium.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net/ethernet/broadcom')
-rw-r--r--drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
index 20fe6a8..0cee4c0 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
@@ -15241,7 +15241,7 @@ static void bnx2x_init_cyclecounter(struct bnx2x *bp)
memset(&bp->cyclecounter, 0, sizeof(bp->cyclecounter));
bp->cyclecounter.read = bnx2x_cyclecounter_read;
bp->cyclecounter.mask = CYCLECOUNTER_MASK(64);
- bp->cyclecounter.shift = 1;
+ bp->cyclecounter.shift = 0;
bp->cyclecounter.mult = 1;
}