diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2016-08-25 09:49:38 (GMT) |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2016-08-25 09:49:38 (GMT) |
commit | 61c04572de404e52a655a36752e696bbcb483cf5 (patch) | |
tree | 48e3f1e1594d96910a41815f20653a6a1163282d /drivers | |
parent | 4935e04ef431c7980ba6e8145ad4c697abccf6b9 (diff) | |
parent | 829bc78aa7628e81a9de717316b85cbee3c5eb86 (diff) | |
download | linux-61c04572de404e52a655a36752e696bbcb483cf5.tar.xz |
Merge branch 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal fixes from Zhang Rui:
- Fix cpu_cooling to have separate thermal_cooling_device_ops
structures for cpus with and without power model, to avoid NULL
dereference in cpufreq_state2power. From Brendan Jackman.
- Fix a possible NULL dereference in imx_thermal driver. From Corentin
LABBE.
- Another two trivial fixes, one typo fix and one deleting module
owner. From Caesar Wang and Markus Elfring.
* 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
thermal: imx: fix a possible NULL dereference
thermal: trivial: fix the typo
Thermal-INT3406: Delete owner assignment
thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 21 | ||||
-rw-r--r-- | drivers/thermal/imx_thermal.c | 4 | ||||
-rw-r--r-- | drivers/thermal/int340x_thermal/int3406_thermal.c | 1 |
3 files changed, 17 insertions, 9 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 3788ed7..a32b417 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -740,12 +740,22 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, } /* Bind cpufreq callbacks to thermal cooling device ops */ + static struct thermal_cooling_device_ops cpufreq_cooling_ops = { .get_max_state = cpufreq_get_max_state, .get_cur_state = cpufreq_get_cur_state, .set_cur_state = cpufreq_set_cur_state, }; +static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = { + .get_max_state = cpufreq_get_max_state, + .get_cur_state = cpufreq_get_cur_state, + .set_cur_state = cpufreq_set_cur_state, + .get_requested_power = cpufreq_get_requested_power, + .state2power = cpufreq_state2power, + .power2state = cpufreq_power2state, +}; + /* Notifier for cpufreq policy change */ static struct notifier_block thermal_cpufreq_notifier_block = { .notifier_call = cpufreq_thermal_notifier, @@ -795,6 +805,7 @@ __cpufreq_cooling_register(struct device_node *np, struct cpumask temp_mask; unsigned int freq, i, num_cpus; int ret; + struct thermal_cooling_device_ops *cooling_ops; cpumask_and(&temp_mask, clip_cpus, cpu_online_mask); policy = cpufreq_cpu_get(cpumask_first(&temp_mask)); @@ -850,10 +861,6 @@ __cpufreq_cooling_register(struct device_node *np, cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus); if (capacitance) { - cpufreq_cooling_ops.get_requested_power = - cpufreq_get_requested_power; - cpufreq_cooling_ops.state2power = cpufreq_state2power; - cpufreq_cooling_ops.power2state = cpufreq_power2state; cpufreq_dev->plat_get_static_power = plat_static_func; ret = build_dyn_power_table(cpufreq_dev, capacitance); @@ -861,6 +868,10 @@ __cpufreq_cooling_register(struct device_node *np, cool_dev = ERR_PTR(ret); goto free_table; } + + cooling_ops = &cpufreq_power_cooling_ops; + } else { + cooling_ops = &cpufreq_cooling_ops; } ret = get_idr(&cpufreq_idr, &cpufreq_dev->id); @@ -885,7 +896,7 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_dev->id); cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev, - &cpufreq_cooling_ops); + cooling_ops); if (IS_ERR(cool_dev)) goto remove_idr; diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index c5547bd..e473548 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -471,8 +471,6 @@ MODULE_DEVICE_TABLE(of, of_imx_thermal_match); static int imx_thermal_probe(struct platform_device *pdev) { - const struct of_device_id *of_id = - of_match_device(of_imx_thermal_match, &pdev->dev); struct imx_thermal_data *data; struct regmap *map; int measure_freq; @@ -490,7 +488,7 @@ static int imx_thermal_probe(struct platform_device *pdev) } data->tempmon = map; - data->socdata = of_id->data; + data->socdata = of_device_get_match_data(&pdev->dev); /* make sure the IRQ flag is clear before enabling irq on i.MX6SX */ if (data->socdata->version == TEMPMON_IMX6SX) { diff --git a/drivers/thermal/int340x_thermal/int3406_thermal.c b/drivers/thermal/int340x_thermal/int3406_thermal.c index a578cd2..1891f34 100644 --- a/drivers/thermal/int340x_thermal/int3406_thermal.c +++ b/drivers/thermal/int340x_thermal/int3406_thermal.c @@ -225,7 +225,6 @@ static struct platform_driver int3406_thermal_driver = { .remove = int3406_thermal_remove, .driver = { .name = "int3406 thermal", - .owner = THIS_MODULE, .acpi_match_table = int3406_thermal_match, }, }; |