summaryrefslogtreecommitdiff
path: root/sound/pci/oxygen
diff options
context:
space:
mode:
authorClemens Ladisch <clemens@ladisch.de>2011-01-10 15:07:11 (GMT)
committerTakashi Iwai <tiwai@suse.de>2011-01-10 15:46:17 (GMT)
commitd353eaa9a8133cdad8c1da23c84f9f529a23f0c2 (patch)
tree12ce94153ebd6427da811575e353a0a259a58cfd /sound/pci/oxygen
parentdd203fa97bd5df18dbb0af5acf3e9a8beea33f74 (diff)
downloadlinux-d353eaa9a8133cdad8c1da23c84f9f529a23f0c2.tar.xz
ALSA: virtuoso: configure correct master clock frequency on the CS2000
The clock output of the CS2000, which is used as master clock for the DACs, was using half the actual master clock frequency for some reason. Using the theoretically correct frequency seems also to work in practice. Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Signed-off-by: Takashi Iwai <tiwai@suse.de>
Diffstat (limited to 'sound/pci/oxygen')
-rw-r--r--sound/pci/oxygen/xonar_pcm179x.c25
1 files changed, 12 insertions, 13 deletions
diff --git a/sound/pci/oxygen/xonar_pcm179x.c b/sound/pci/oxygen/xonar_pcm179x.c
index 2e31b81..fce55fa 100644
--- a/sound/pci/oxygen/xonar_pcm179x.c
+++ b/sound/pci/oxygen/xonar_pcm179x.c
@@ -467,7 +467,7 @@ static void xonar_st_init(struct oxygen *chip)
oxygen_write16(chip, OXYGEN_I2S_A_FORMAT,
OXYGEN_RATE_48000 | OXYGEN_I2S_FORMAT_I2S |
- OXYGEN_I2S_MCLK_128 | OXYGEN_I2S_BITS_16 |
+ OXYGEN_I2S_MCLK_256 | OXYGEN_I2S_BITS_16 |
OXYGEN_I2S_MASTER | OXYGEN_I2S_BCLK_64);
xonar_st_init_i2c(chip);
@@ -635,41 +635,40 @@ static void update_cs2000_rate(struct oxygen *chip, unsigned int rate)
u8 rate_mclk, reg;
switch (rate) {
- /* XXX Why is the I2S A MCLK half the actual I2S MCLK? */
case 32000:
- rate_mclk = OXYGEN_RATE_32000 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_32000 | OXYGEN_I2S_MCLK_512;
break;
case 44100:
if (data->os_128)
- rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_512;
else
- rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_128;
+ rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_256;
break;
default: /* 48000 */
if (data->os_128)
- rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_512;
else
- rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_128;
+ rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_256;
break;
case 64000:
- rate_mclk = OXYGEN_RATE_32000 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_32000 | OXYGEN_I2S_MCLK_512;
break;
case 88200:
- rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_512;
break;
case 96000:
- rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_512;
break;
case 176400:
- rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_44100 | OXYGEN_I2S_MCLK_512;
break;
case 192000:
- rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_256;
+ rate_mclk = OXYGEN_RATE_48000 | OXYGEN_I2S_MCLK_512;
break;
}
oxygen_write16_masked(chip, OXYGEN_I2S_A_FORMAT, rate_mclk,
OXYGEN_I2S_RATE_MASK | OXYGEN_I2S_MCLK_MASK);
- if ((rate_mclk & OXYGEN_I2S_MCLK_MASK) <= OXYGEN_I2S_MCLK_128)
+ if ((rate_mclk & OXYGEN_I2S_MCLK_MASK) <= OXYGEN_I2S_MCLK_256)
reg = CS2000_REF_CLK_DIV_1;
else
reg = CS2000_REF_CLK_DIV_2;