Age | Commit message (Collapse) | Author |
|
|
|
The FW command output length should be only the length of struct
mlx5_cmd_fc_bulk out field. Failing to do so will cause the memcpy
call which is invoked later in the driver to write over wrong memory
address and corrupt kernel memory which results in random crashes.
This bug was found using the kernel address sanitizer (kasan).
Fixes: a351a1b03bf1 ('net/mlx5: Introduce bulk reading of flow counters')
Signed-off-by: Roi Dayan <roid@mellanox.com>
Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Add interfaces to allow the creation and destruction of a
LAG demux flow table.
It is a special flow table used during LAG for redirecting
non user-mode packets from PF0 to PF1 root ft, if a packet was
received on phys port two.
Signed-off-by: Aviv Heller <avivh@mellanox.com>
Reviewed-by: Maor Gottlieb <maorg@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
Signed-off-by: Leon Romanovsky <leon@kernel.org>
|
|
Implement low-level commands to support vxlan encapsulation.
Signed-off-by: Ilya Lesokhin <ilyal@mellanox.com>
Signed-off-by: Hadar Hen Zion <hadarh@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
Signed-off-by: Leon Romanovsky <leon@kernel.org>
|
|
Now as all commands use mlx5 ifc interface, instead of doing two calls
for executing a command we embed command status checking into
mlx5_cmd_exec to simplify the interface.
Also we do here some cleanup for redundant software structures
(inbox/outbox) and functions and improved command failure output.
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
Signed-off-by: Leon Romanovsky <leon@kernel.org>
|
|
This commit utilize the ability of ConnectX-4 to bulk read flow counters.
Few bulk counter queries could be done instead of issuing thousands of
firmware commands per second to get statistics of all flows set to HW,
such as those programmed when we offload tc filters.
Counters are stored sorted by hardware id, and queried in blocks (id +
number of counters).
Due to hardware requirement, start of block and number of counters in a
block must be four aligned.
Reviewed-by: Or Gerlitz <ogerlitz@mellanox.com>
Signed-off-by: Amir Vadai <amir@vadai.me>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
When adding a flow steering rule with a counter, need to supply a
destination of type MLX5_FLOW_DESTINATION_TYPE_COUNTER, with a pointer
to a struct mlx5_fc.
Also, MLX5_FLOW_CONTEXT_ACTION_COUNT bit should be set in the action.
Signed-off-by: Amir Vadai <amirva@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Getting packet/byte statistics on flows is done through flow counters.
Implement the firmware commands to alloc, free and query flow counters.
Signed-off-by: Amir Vadai <amirva@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Update the relevant flow steering device structs and commands to
support vport.
Update the flow steering core API to receive vport number.
Add ingress and egress ACL flow table name spaces.
Add ACL flow table support:
* ACL (Access Control List) flow table is a table that contains
only allow/drop steering rules.
* We have two types of ACL flow tables - ingress and egress.
* ACLs handle traffic sent from/to E-Switch FDB table, Ingress refers to
traffic sent from Vport to E-Switch and Egress refers to traffic sent
from E-Switch to vport.
* Ingress ACL flow table allow/drop rules is checked against traffic
sent from VF.
* Egress ACL flow table allow/drop rules is checked against traffic sent
to VF.
Signed-off-by: Mohamad Haj Yahia <mohamad@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
We need to handle flow table entry destinations only if the action
associated with the rule is forwarding (MLX5_FLOW_CONTEXT_ACTION_FWD_DEST).
Fixes: 26a8145390b3 ('net/mlx5_core: Introduce flow steering firmware commands')
Signed-off-by: Amir Vadai <amir@vadai.me>
Signed-off-by: Maor Gottlieb <maorg@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Flow tables from different priorities should be chained together.
When a packet arrives we search for a match in the
by-pass flow tables (first we search for a match in priority 0
and if we don't find a match we move to the next priority).
If we can't find a match in any of the bypass flow-tables, we continue
searching in the flow-tables of the next priority, which are the
kernel's flow tables.
Setting the miss flow table in a new flow table to be the next one in
the list is performed via create flow table API. If we want to change an
existing flow table, for example in order to point from an
existing flow table to the new next-in-list flow table, we use the
modify flow table API.
Signed-off-by: Maor Gottlieb <maorg@mellanox.com>
Signed-off-by: Moni Shoua <monis@mellanox.com>
Signed-off-by: Matan Barak <matanb@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Introduce the modify flow table command. This command is used when
we want to change the next flow table of an existing flow table.
The next flow table is defined as the table we search (in order
to find a match), if we couldn't find a match in any of the flow table
entries in the current flow table.
Signed-off-by: Maor Gottlieb <maorg@mellanox.com>
Signed-off-by: Moni Shoua <monis@mellanox.com>
Signed-off-by: Matan Barak <matanb@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The root Flow Table for each Flow Table Type is defined,
by default, as the Flow Table with level 0.
In order not to use an empty flow tables and introduce new hops,
but still preserve space for flow-tables that have a priority
greater(lower number) than the current flow table, we introduce this
new set root flow table command.
This command tells the HW to start matching packets from the
assigned root flow table.
This command is used when we create new flow table with level lower than the
current lowest flow table or it is the first flow table.
Signed-off-by: Maor Gottlieb <maorg@mellanox.com>
Signed-off-by: Moni Shoua <monis@mellanox.com>
Signed-off-by: Matan Barak <matanb@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
Introduce new Flow Steering (FS) firmware commands,
in-order to support the new flow steering infrastructure.
Signed-off-by: Maor Gottlieb <maorg@mellanox.com>
Signed-off-by: Moni Shoua <monis@mellanox.com>
Signed-off-by: Matan Barak <matanb@mellanox.com>
Signed-off-by: Saeed Mahameed <saeedm@mellanox.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|